EasyManuals Logo

Keithley 2230G-30-3 User Manual

Keithley 2230G-30-3
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #84 background imageLoading...
Page #84 background image
Section
5: SCPI command reference Series 2230G Triple-Channel Power Supplies
User's Manual
5-32 2230G-900-01 Rev. A / June 2018
Example
OUTP:PROT:CLE
Clears the set protection state of the power supply.
See also
None
[SOURce:]OUTPut:SERies[:STATe]
This command sets the series synchronization state of channel 1 (CH1) and channel 2 (CH2). If channel 3 (CH3)
and CH1 or CH3 and CH2 are in parallel synchronization states, an error is generated after the command is
executed. The query version of this command gets the synchronization state of CH1 and CH2.
Group
Source
Syntax
[SOURce:]OUTPut:SERies[:STATe] <BOOL>
[SOURce:]OUTPut:SERies[:STATe]?
Arguments
<BOOL> ON|OFF|0|1 The series synchronization state.
Default value
OFF
Returns
0|1
1 means enable and 0 means disable.
Example
OUTP:SER ON
Sets the series synchronization state to ON.
See also
None