Triple-Channel Power Supplies User's Manual Section 5:
2230G-900-01 Rev. A / June 2018 5-37
[SOURce:]VOLTage[:LEVel]:UP[:IMMediate][:AMPLitude]
This command increases the voltage value of the present channel by one step, as specified by the
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement] command.
Group
Source
Syntax
[SOURce:]VOLTage[:LEVel]:UP[:IMMediate][:AMPLitude]
Arguments
None
Default value
None
Returns
Not applicable
Example
VOLT:UP
Increases the voltage value of the present channel by one step.
See also
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement] (on page 5-36)
[SOURce:]VOLTage:LIMit[:LEVel]
This command sets the voltage limit for the present channel. The query version of this command returns the
voltage limit for the present channel.
Group
Source
Syntax
[SOURce:]VOLTage:LIMit[:LEVel] <NRf>
[SOURce:]VOLTage:LIMit[:LEVel]?
Arguments
<NRf> MIN|Max|DEF The voltage limit, 0 to the maximum rated voltage.
Default value
The maximum rated voltage
Returns
Not applicable