206 Keysight M8070A Programming Guide
5 SCPI Command Reference
Description This command selects the signal source for the instrument’s output. This is
only valid for certain clock outputs.
This query returns the present state.
This SCPI is supported by M8045A.
Example :OUTP:CONF:SOUR ‘M1.ClkOut1’,CLE
:OUTPut:DRATe?
Syntax :OUTPut:DRATe? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', 'M*.DataOut', or ‘M1.ClkOut’
Description This query returns data rate for the output channel.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A, M8195A
and M8045A.
Example :OUTP:DRAT? 'M1.DataOut1'
:OUTPut:POLarity[?]
Syntax :OUTPut:POLarity ‘identifier’, <NORMal|INVerted>
:OUTPut:POLarity? ‘identifier’
Input
Parameters
‘identifier’: 'M1.TrigOut', 'M*.DataOut1', 'M*.DataOut2', 'M*.CtrlOutA',
'M*.SysOutA', 'M*.SysOutB', or 'M*.DataOut'
<NORmal|INVerted>: Set output polarity to normal or inverted.
Return Range NORM|INV
Description This command sets the output polarity to either normal or inverted.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
Example :OUTP:POL ‘M1.DataOut1’, INV
:OUTPut:TVOLtage[?]
Syntax :OUTPut:TVOLtage ‘identifier’, <NRf>
:OUTPut:TVOLtage? ‘identifier’

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Summary

Keysight M8000 Series of BER Test Solutions

Safety Summary

Covers general safety precautions, environment conditions, and handling instructions for instrument operation.

1 Programming Basics

Modular Configuration

Discusses the modular configuration of instruments for remote programming.

Using Identifiers

Explains the use of Location, Group Name, and Measurement Name identifiers.

2 Recommended Programming Techniques

Output Protection

Covers pattern generator output termination and protection algorithm.

Controlling the Output Levels

Explains how to set output levels using parameters like Vhigh, Vlow, Vamptl, Voffs.

Allowing the M8020A/M8030A/M8040A to Settle

Explains how instruments react to pattern changes and the time needed to settle.

3 Programming Examples

Initializing the Connection

Shows how to initialize the connection to the instrument using the ResourceName.

4 SCPI Command Language

SCPI Command Language - Introduction

Explains SCPI as the universal programming language for instrument control.

Important Points about SCPI

Covers key areas for SCPI usage: Instrument Model, Command Syntax, and Sending Commands.

Sending Commands to the M8020A/M8030A/M8040A

Details how to send commands, including an overview and using VISA.

5 SCPI Command Reference

Subsystems

Divides SCPI commands into subsystems reflecting instrument functionality.

PLUGin Subsystem

Describes the plugin interface for integrating C# assemblies.