Keysight M8070A Programming Guide 219
SCPI Command Reference 5
:OUTPut:DEEMphasis:CURSor:MAGNitude(0|1|2|3|4|5|6|7)[?]
Syntax :OUTPut:DEEMphasis:CURSor:MAGNitude(0|1|2|3|4|5|6|7)
'Identifier',<NRf>
:OUTPut:DEEMphasis:CURSor:MAGNitude(0|1|2|3|4|5|6|7)? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1' or 'M*.DataOut2'
Return Range <NRf>
Description This command sets the cursor magnitude as a signed value. The suffix
selects the cursor to be addressed. The number of available cursors
depends on the product number.
The M8045A supports cursors 0 to 3, where the main cursor is always
cursor 2.
This query returns the present setting.
This SCPI is supported by M8045A.
Example :OUTP:DEEM:CURS:MAGN1 'M1.DataOut1',-0.05
:OUTP:DEEM:CURS:MAGN1? 'M1.DataOut1'