220 Keysight M8070A Programming Guide
5 SCPI Command Reference
:OUTPut:DEEMphasis:CURSor:MAIN:AUTO[?]
Syntax :OUTPut:DEEMphasis:CURSor:MAIN:AUTO 'Identifier',<ON|OFF|1|0>
:OUTPut:DEEMphasis:CURSor:MAIN:AUTO? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1' or 'M*.DataOut2'
Return Range ON|OFF|1|0
Description This command controls whether the main cursor magnitude shall be
calculated automatically in order to maintain the overall peak to peak
amplitude constant, or whether the main cursor magnitude can be
controlled manually.
When this is set to ON, then the main cursor magnitude is calculated to
fulfill the sum below.
This query returns the present state.
This SCPI is supported by M8045A.
Example :OUTP:DEEM:CURS:MAIN:AUTO 'M1.DataOut1',OFF
:OUTP:DEEM:CURS:MAIN:AUTO? 'M1.DataOut1'