:INPut:CDR:RELOck
Syntax :INPut:CDR:RELOck ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn'
Description This command execute a full CDR relock.
This SCPI is applicable for M8062A.
Example :INPut:CDR:RELOck ‘M2.DataIn’
:INPut:CDR:HIGHTD[?]
Syntax :INPut:CDR:HIGHTD ‘identifier’, <ON|OFF|1|0>
:INPut:CDR:HIGHTD? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn'
<ON|OFF|1|0>: Set the High Transition Density state to ON or OFF.
Return Range 0|1
Description This command sets the High Transition Density state to ON or OFF.
This SCPI is applicable for M8062A.
Example :INPut:CDR:HIGHTD ‘M2.DataIn’, 1
:INPut:CDR:OPTimize
Syntax :INPut:CDR:OPTimize ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn'
Description This command invokes the M8062A CDR optimization at the current data
rate and optionally applied jitter.
This SCPI is applicable for M8062A.
Example :INPut:CDR:OPTimize ‘M2.DataIn’