268 Keysight M8070A Programming Guide
5 SCPI Command Reference
:N1000:CRECovery:LSELect:AUTomatic[?]
Syntax :N1000:CRECovery:LSELect:AUTomatic <identifier>,{ON | OFF | 1 | 0}
:N1000:CRECovery:LSELect:AUTomatic? <identifier>
Input
Parameters
‘identifier’: ‘DCA*.SLOT*'
ON | OFF | 1 | 0
Description This command enables or disables automatic selection of the type 2 loop
transition frequency.
This query returns the present state.
This SCPI is applicable for M8046A.
Example :N1000:CREC:LSEL:AUTO "DCA1.SLOT1",ON
For detailed documentation, see :CRECovery{n}:LSELect:AUTO in the
FlexDCA online help.
:N1000:CRECovery:ODRatio[?]
Syntax :N1000:CRECovery:ODRatio <identifier>,
{SUB32|SUB16|SUB8|SUB4|SUB2|UNITy|SUPer2|SUPer4|SUPer8}
:N1000:CRECovery:ODRatio? <identifier>
Input
Parameters
‘identifier’: ‘DCA*.SLOT*'
SUB32 | SUB16 | SUB8 | SUB4 | SUB2 | UNITy | SUPer2 | SUPer4 | SUPer8
Description This command sets the recovered clock’s output divide ratio.
This query returns the present state.
This SCPI is applicable for M8046A.
Example :N1000:CREC:ODR "DCA1.SLOT1",SUB2
For detailed documentation, see :CRECovery{n}:ODRatio in the FlexDCA
online help.

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals