402 Keysight M8070A Programming Guide
5 SCPI Command Reference
:PLUGin:EDIagram:ACQuisition:PERSistence[?]
Syntax :PLUGin:EDIagram:ACQuisition:PERSistence 'Identifier', <INF | FTIM>
:PLUGin:EDIagram:ACQuisition:PERSistence? 'Identifier',
Input
Parameters
Identifier: 'MyMeasurement'
Return Range INF | FTIM
Description This command sets the criteria for persistence. Persistence could be
infinite or fixed time.
The query returns the current setting.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example :PLUG:EDI:ACQ:PERS 'MyMeasurement',INF
:PLUGin:EDIagram:ACQuisition:TIME[?]
Syntax :PLUGin:EDIagram:ACQuisition:TIME 'Identifier', <NRf>
:PLUGin:EDIagram:ACQuisition:TIME? 'Identifier'
Input
Parameters
Identifier: 'MyMeasurement'
Return Range 50s to 216ks
Description This command allows the user to specify the persistence time.
The query returns current setting.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example :PLUG:EDI:ACQ:TIME 'MyMeasurement', 80