:PLUGin:CCAPture:FETCh:PATTern[:DATA]:HOLDoff?
Syntax :PLUGin:CCAPture:FETCh:PATTern[:DATA]:HOLDoff?
'identifier' [,‘Location’]
Input
Parameters
identifier: ‘Name of Measurement’
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’
Description This command returns the actual holdoff i.e. number of data bits captured
before the trigger event. Returned value of this query is only valid when
capture measurement is finished.
This SCPI is applicable for M8041A and M8051A.
Example :PLUGin:CCAPture:FETCh:PATTern:DATA:HOLDoff? 'MyMeasurement',
‘M1.DataIn1’
Return: (“M1.DataIn1”, ...)
:PLUGin:CCAPture:FETCh:PATTern[:DATA]:DEPTh?
Syntax :PLUGin:CCAPture:FETCh:PATTern[:DATA]:DEPTh? 'identifier' [,‘Location’]
Input
Parameters
identifier: ‘Name of Measurement’
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’
Description This command returns the total number of data bits captured. Returned
value of this query is only valid when capture measurement is finished.
This SCPI is applicable for M8041A and M8051A.
Example :PLUGin:CCAPture:FETCh:PATTern:DATA:DEPTh? 'MyMeasurement',
‘M1.DataIn1’
Return: (“M1.DataIn1”, ...)

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals