An Offset value is provided after programming. A trigger starts the sequence.
The following sequence advancement modes are available:
Auto: The sequence is executed the number of times specified by its loop count.
Then the last sample is played at the end.
Repeat: This advancement mode is quite the same like “Auto” with the difference
that an advancement event is required at the end.
Single: An advancement event is required for each sequence repetition.
Conditional: The sequence is played infinitely after receiving a trigger. After being
stopped (See SCPI command :ABORt[1|2]) the offset value is played.
The following segment advancement modes are available:
Auto
Conditional (Advancement Event)
Repeat (Advancement Event)
Single (Advancement Event)