8 General Programming
264 M8190A User’s Guide
Table 8-19: Segment Loop Count
Bit
Width
Meaning
Data
Idle
Config
31:0
32
Number of segment iterations (1..4G-1)
X
N/A
N/A
Table 8-20: Segment Id
Bit
Width
Meaning
Data
Idle
Config
31:19
13
Reserved
X
N/A
X
18:0
19
Segment id (1 .. 512K)
X
N/A
X
Table 8-21: Segment Start Offset
Bit
Width
Meaning
Data
Idle
Config
31:0
32
Allows specifying a segment start address in samples, if only part of a
segment loaded into waveform data memory is to be used. The value
must obey the granularity of the selected waveform output mode.
X
N/A
X
Table 8-22: Segment End Offset
Segment End Offset
Bit
Width
Meaning
Data
Idle
Config
31:0
32
Allows specifying a segment end address in samples, if only part of a
segment loaded into waveform data memory is to be used. The value
must obey the granularity of the selected waveform output mode. You
can use the value 0xffffffff, if the segment end address equals the last
sample in the segment.
X
N/A
X
Table 8-23: Command Code
Command Code
Bit
Width
Meaning
Data
Idle
Config
31:16
16
Action table id
N/A
N/A
X
15:0
16
Command code
0: Idle Delay
1: Configuration
N/A
X