:POINts? (@chanlist) Returns the number of points
:FUNCtion <function>, (@chanlist) Selects the Arb function (for backward compatibility)
:SHAPe <function>, (@chanlist) Selects the Arb function (replaces ARB:FUNCtion)
:TYPE CURRent|VOLTage, (@chanlist) Selects the Arb type (replaces ARB:FUNCtion)
:SEQuence
:COUNt <value>|INFinity, (@chanlist) Sets the number of times the sequence is repeated
:LENGth? (@chanlist) Returns the number of steps in the sequence
:QUALity? (@chanlist) Returns the quality of the waveforms in the sequence
:RESet (@chanlist) Resets the sequence to its power-on default setting
:STEP
:COUNt <value>|INFinity, <step#> (@chanlist) Sets the number of times the sequence step is repeated
:CURRent <function>, <step#> (@chanlist) Programs the waveform steps within a current sequence
:FUNCtion
:SHAPe <function>, <step#>, (@chanlist) Creates a new sequence step
:PACing DWELl|TRIGger, <step#> (@chanlist) Specifies the type of pacing for the step
:VOLTage <function>, <step#> (@chanlist) Programs the waveform steps within a voltage sequence
:TERMinate
:LAST 0|OFF|1|ON, (@chanlist) Sets the sequence termination mode
:TERMinate
:LAST 0|OFF|1|ON, (@chanlist) Sets the Arb termination mode
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the output current.
:TRIGgered
[:AMPLitude] <value>, (@chanlist) Sets the triggered output current
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the positive current limit. (only on N678xA SMU, N6783A)
:COUPle 0|OFF|1|ON, (@chanlist) Sets the current limit tracking state. (only on N678xA SMU)
:NEGative
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the negative current limit. (only on N678xA SMU, N6783A-BAT)
:MODE FIXed|STEP|LIST|ARB, (@chanlist) Sets the transient mode.
:PROTection
:DELay
[:TIME] <value>, (@chanlist) Sets the over-current protection delay.
:STARt SCHange|CCTRans, (@chanlist) Specifies what starts the over-current protection delay timer.
:STATe 0|OFF|1|ON, (@chanlist) Enables/disables the over-current protection.
:RANGe <value>, (@chanlist) Sets the output current range.