EasyManua.ls Logo

Keysight N9010B - Scale;Div; Ref Position

Keysight N9010B
2650 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 VMA Mode
3.1 Digital Demod Measurement
Remote Command
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:RLEVel <real>
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:RLEVel?
Example Set the Y ref value of the third window to 20:
:DISP:DDEM:WIND3:Y:RLEV 20
Query the Y ref value of the third window:
:DISP:DDEM:WIND3:Y:RLEV?
Preset Depends on trace data
State Saved Saved in instrument state
Min/Max -9.9E+37/9.9E+37
Annotation The reference value is displayed above the graticule with the title “Ref Value”
Scale/Div
Controls the Y scale per division of the selected trace.
Remote Command
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:PDIVision <real>
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:PDIVision?
Example
:DISP:DDEM:WIND3:Y:PDIV 10
Set the Y scale/div of the third window to 10
:DISP:DDEM:WIND3:Y:PDIV?
Query the Y scale/div of the third window
Preset Depends on trace data
State Saved Yes
Min/Max -9.9E+37/9.9E+37
Annotation Upper left corner of trace grid, same gray as grid
Ref Position
Positions the reference level at the top, center, or bottom of the Y Scale display.
Changing the reference position does not change the reference level value.
Remote
Command
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:RPOSition TOP | CENTer | BOTTom
:DISPlay:DDEMod:WINDow[1]|2|…|6:Y[:SCALe]:RPOSition?
Example
:DISP:DDEM:WIND3:Y:RPOS TOP
Set the Y ref position of the third window to TOP
:DISP:DDEM:WIND3:Y:RPOS?
Query the Y ref position of the third window
Vector Modulation Analyzer Mode User's &Programmer's Reference 230