7 Save/Recall/Print
7.3 Save
Resolution Bandwidth Shape Gaussian
RRC Filter Alpha 0.22
RRC Filter BW 3840000
RRC Filter State FALSE
Span 3000000
Sweep Points 1001
Sweep Time 0.004933333
Sweep Time Auto TRUE
TriggerSource Free
Video Bandwidth 270000
Y Axis Unit DecibelMilliwatt
MeasResult1 MeasResult2
-76.8141133132837 -95.29174
-139.824413269924 -94.99601
-94.95281
-95.17146
7.3.15 OBW Meas Results File Contents
The first lines in the OBW Meas results file consist of header information, as follows.
File ID string, which is “MeasResult”
Measurement ID following Mode ID, which is “SA:OBW” for example.
Firmware rev and model number
Option string
Auto Sweep Time Rules
Average Mode
Average Number
Average State
Center Frequency
Detector
Electrical Atten
Vector Modulation Analyzer Mode User's &Programmer's Reference 2371