Kinco FD5 AC series servo driver user manual
Chatper 6 Operation mode introduction
93
Option 2: Buy the ENCDG-(4)-
GU-BT5 cable plus BAT-FD5
battery box accessory, which can
be mounted and fixed to the
bottom of the drive.
When the battery voltage is below 3.1V, the driver appears the warning status word 0001 and the panel will flash 000.1, but the
driver will not alarm stop at this time. Under the condition that the driver remains properly powered and the encoder cable is
properly connected, the battery replacement will not cause multiple data loss. When the battery voltage is lower than 2.5V, the
encoder UVW fault or internal fault (fault code 000.4) occurs in the driver. At this time, the motor stops running, the data is lost in
multiple turns, and the absolute encoder needs to be re-initialized after the battery is replaced.