EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Adjusting the DP Magnification

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV
1-3-47
U070 Adjusting the DP magnification
Description
Adjusts the DP original scanning speed.
Purpose
Perform this adjustment if the magnification is incorrect in the auxiliary scanning direction when
the DP is used.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original on the DP and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.l
Adjustment: [Y Scan Zoom]
1. Change the setting value using the +/- keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Figure 1-3-11
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Setting
range
Initial
setting
Change in
value per step
Sub Scan(F)
Magnification in the auxiliary
scanning direction of CCD
(first side)
-125 to 125 0 0.02 %
Sub Scan(B)
Magnification in the auxiliary
scanning direction of CCD
(second side)
-125 to 125 0 0.02 %
Original Copy
example 1
Copy
example 2

Table of Contents