Kyocera TASKalfa 2550ci - Setting the Voltage for the Intermediate Transfer Cleaning

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV-1
1-3-64
U107 Setting the voltage for the intermediate transfer cleaning
Description
Sets the control voltage for the intermediate transfer cleaning.
Purpose
To change the setting when the offset by a defective cleaning of the transfer belt is generate.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Setting
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Belt(A)
Correction value of belt A
Belt(B)
Correction value of belt B
Belt(C)
Correction value of belt C
Display Description
Setting
range
Initial
setting
Full
Full speed printing of color 0 to 200
13/90/90
Half
Half speed printing of color 0 to 200
9/45/45
3/4 75% of full speed printing of color
0 to 200
10/68/68
B/W Full Full speed printing of monochrome
0 to 200
13/75/75
B/W Half Half speed printing of monochrome
0 to 200
10/35/35
B/W 3/4 75% of full speed printing of
monochrome
0 to 200
9/53/53