EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Setting Developer Bias

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV
1-3-71
U140 Setting developer bias
Description
Setting the value of various developer bias.
Purpose
To check and setting the value of developer bias.
Method
1. Press the start key.
2. Select the item to be set.
Setting: [Mag DC/Sleeve DC/Clock Freq/Clock Duty/AC Ctrl]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
3. Press the start key. The value is set.
Item No. Description
Display Description
Mag DC
Setting the value of magnet DC bias.
Sleeve DC
Setting the value of sleeve DC bias.
Clock Freq
Setting the value of clock frequency.
Clock Duty
Setting the value of clock duty.
AC Ctrl
Setting the value of AC control voltage.
On Timing
Setting the value of developer On timing.
Off Timing
Setting the value of developer Off timing.
Display Description Initial setting
C Setting the value of cyan.
480/180/36/37/1500
M Setting the value of magenta.
480/180/36/37/1500
Y Setting the value of yellow.
450/150/36/37/1500
K Setting the value of black.
450/150/36/37/1500
Remove C
Setting the value of remove cyan. 100/200/36/33/1150
Remove M
Setting the value of remove magenta. 100/200/36/33/1150
Remove Y
Setting the value of remove yellow. 100/200/36/33/1150
Remove K
Setting the value of remove black. 100/200/36/33/1150
Remove C Half
Setting the value of remove cyan Half. 350/150/36/33/1150
Remove M Half
Setting the value of remove magenta Half. 350/150/36/33/1150
Remove Y Half
Setting the value of remove yellow Half. 350/150/36/33/1150
Remove K Half
Setting the value of remove black Half. 350/150/36/33/1150