EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Page 197

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV-1
1-3-125
U464
Setting: [Bias Target/Gamma Target]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
3. Press the start key. The value is set.
Method: [Calib]
1. Select the item to be set
2. Press the start key. The operation starts.
3. To stop operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description Setting
range
Initial set-
ting
C Setting of target (Cyan) 10 to 1000 760/300
M Setting of target (Magenta) 10 to 1000 760/300
Y Setting of target (Yellow) 10 to 1000 750/300
K Setting of target (Black) 10 to 1000 820/400
Display Description
Regist Executes the calibration to correct registration.
Gamma Executes the calibration to quantities of light.
Paper Int Executes the calibration between paper.
Color Regist Executes the calibration to color registration.

Table of Contents

Other manuals for Kyocera TASKalfa 2550ci

Related product manuals