2MV-C
1-4-42
9150 Sensor error in coin vender
change (Yen 500)
Change is empty despite
change is enough.
Coin jam in the
change tube
Check visually and remedy.
Poor contact in the
connector.
Check if the change empty sensor is intact.
Defective change
empty sensor.
Replace the coin mec.
Defective coin
vender control
PWB.
9160 Coin vender pay-out error
Coin is paid out despite the
pay-out motor is determined
not active.
Defective pay-out
motor.
Replace the coin mec.
9170 Coin vender pay-out sensor
error
Coin is paid out despite the
pay-out motor is determined
not active.
Change jam at the
pay-out.
Check visually and remedy.
Defective pay-out
motor.
Replace the coin mec.
Defective pay-out
sensor.
9500 ISC PWB error A
Main PWB
ISC PWB
1. Reinsert the connector if its connection
is loose.
Main PWB (YC25) and ISC PWB (YC4)
2. Replace the main PWB (see page 1-5-
43).
3. Replace the ISC PWB
4. Contact the Service Support.
9510
ISC PWB error B
Main PWB
ISC PWB
1. Reinsert the connector if its connection
is loose.
Main PWB (YC25) and ISC PWB (YC4)
2. Replace the main PWB (see page 1-5-
43).
3. Replace the ISC PWB
4. Contact the Service Support.
9520
ISC PWB error C
Main PWB
ISC PWB
1. Reinsert the connector if it its connection
is loose.
Main PWB (YC25) and ISC PWB (YC4)
2. Replace the main PWB (see page 1-5-
43).
3. Replace the ISC main PWB
4. Contact the Service Support.
Code Contents Causes
Check procedures/
corrective measures