8 MAINTENANCE AND SERVICE
LACO Technologies TITAN VERSA Operations and Maintenance Manual 151
Oil Mist Eliminator Maintenance
Change the oil mist eliminator (OME) filter cartridge (P/N: PFPKE07025T) every
3000 hours or 18 months (whichever comes first).
1. Twist top half of OME to remove cover.
2. Remove bolt on top of filter. Be sure to keep o-ring under bolt attached to the bolt.
3. Replace filter element.
4. Lightly oil all o-rings with pump fluid.
5. Assemble in reverse order.