EasyManua.ls Logo

LACO Technologies TITAN VERSA C - VERSA T Dry Pump Maintenance

LACO Technologies TITAN VERSA C
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 MAINTENANCE AND SERVICE
152 TITAN VERSA Operations and Maintenance Manual LACO Technologies
Pump Repair Options
There are three pump repair options summarized in Table 58 below.
Tower Wet Pump Repair Options
Maintenance Task
Part Number
Maintenance Interval
Level
Site
Change pump oil
LVOEZUNO6
1500 hours or 6 months
2
OS
Change oil mist
eliminator filter
PFPKE07025T
3000 hours or 18
months
2
OS
Repair or exchange
pump
LS-TVT-1 (Repair)
LS-TVT-2C (Exchange)
LS-TVT-2L (Exchange)
24000 hours or 48
months
2-3
OS or
LS
Replace pump
PFPKD07711
36000 hours or 72
months
2-3
OS or
LS
Other Pump Parts
VERSA T Pump Parts
Part Number
Description
LMSA119457
UNO 6 hose assembly
LMK-TVT-7
UNO 6 oil drain line
LMK-TVT-8
UNO 6 oil fill line
LMK-TVT-6
UNO 6 oil drain-back assembly
CAUTION: Dry pumps do not typically have short term maintenance
concerns but can potentially require major long-term repair if two-
year maintenance is not performed. Customers with leak detectors
in critical applications should consider purchasing a spare pump for
unplanned maintenance.
Accessing the MVP-030 Pumps
To access the MSP-030 pumps on the VERSA T model it is necessary to remove the
bottom front and back covers (see Removing Covers).

Table of Contents

Related product manuals