44
LeeBoy 8515E Conveyor Paver 4-25
Operation
Gauge
Figure 4-49. Gauge and Cable Rod End
1. Before paving, refer to the screed elevation gauge
(located on both sides of the operator platform, left
side shown). (Figure 4-49)
2. Raise or lower the screed until the cable rod end is
ush with “0”on the decal.
3. Set the Tow switch on both sides to thicker or
thinner for desired asphalt thickness. (Figure 4-50)
4. Slowly move joysticks forward.
5. Use the Tow switch on both sides of the control
panel to adjust mat thickness as you pave. (Figure
4-50)
Figure 4-50. Tow Switches
6. While paving, refer to both screed elevation gauges
to make minor screed adjustments using the elec-
tric ight screw.
Operating in AUTO mode:
You will need the TopCon sonic grade/slope system to
operate in AUTO mode. (See Page 4-35) The TopCon
control system must be connected to operate in AUTO
mode.
• The Tow Up and Down switches will not function in
AUTO mode unless joysticks are in neutral.
Under Auger Material Cut-Offs Under Auger Material Cut-Offs
The Under Auger Material Cut-Offs are another impor-
tant function of the paver, used primarily to control
the ow of asphalt to the screed and hydraulic screed
extensions. (Figure 4-48) Cut-offs can be used to limit
material ow when making narrow passes at the begin-
ning and ending of each pass or pull. Proper use of the
cut-offs minimizes clean-up at the end of pulls.
Cut-O Switches
Figure 4-48. Under Auger Material Cut-Off Switches
• The right and left cut-off switches are used to open
and close the cut-off gates and are located on both
the main control panel and the screed controls.
• Pushing the switch to the OPEN positions increases
asphalt ow to the screed. Pushing the switch to
the CLOSED position decreases asphalt ow to the
screed.
NEVER back up with the cut-offs
open. The cut-offs are designed to break away from
cylinders when hitting a manhole or other object
when moving forward, but not in reverse.
Electric Flight Screw Electric Flight Screw
The electric ight screw is an added convenience to the
operator for making automatic, minor adjustments to
mat thickness while paving.
A screed height gauge is located on both sides of the
paver to provide the operator with a quick reference to
the location of the electric screw. (Figure 4-49)
NOTE: The Grade Control switch on the main control
panel must be set to GRADE for this feature to
operate.