Install a 2.5-/3.5-inch hot-swap drive
Follow instructions in this section to install a 2.5-inch or 3.5-inch hot-swap drive.
About this task
Attention: 
•  Read “Installation Guidelines” on page 121 and “Safety inspection checklist” on page 122 to ensure that 
you work safely.
•  Touch the static-protective package that contains the drive to any unpainted metal surface on the 
solution; then, remove the drive from the package and place it on a static-protective surface.
•  Make sure you save the data on your drive, especially if it is part of a RAID array, before you remove it 
from the server.
•  To avoid damage to the drive connectors, make sure that the server top cover is in place and fully closed 
whenever you install or remove a drive.
•  To make sure that there is adequate system cooling, do not operate the server for more than two minutes 
without either a drive or a drive bay filler installed in each bay.
•  Before you make changes to drives, drive controllers (including controllers that are integrated on the 
system board), drive backplanes, or drive cables, back up all important data that is stored on drives.
•  Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration 
information.
The following notes describe the type of drives that the server supports and other information that you must 
consider when you install a drive. For a list of supported drives, see 
https://static.lenovo.com/us/en/ 
serverproven/index.shtml
. 
•  Locate the documentation that comes with the drive and follow those instructions in addition to the 
instructions in this chapter.
•  The electromagnetic interference (EMI) integrity and cooling of the solution are protected by having all 
bays and PCI and PCIe slots covered or occupied. When you install a drive, PCI, or PCIe adapter, save the 
EMC shield and filler panel from the bay or PCI or PCIe adapter slot cover in the event that you later 
remove the device.
•  For a complete list of supported optional devices for the server, see 
https://static.lenovo.com/us/en/ 
serverproven/index.shtml
.
•  Depending on your server configuration for 4-DW GPU Model, the following drive types can be installed 
into each drive cage with their corresponding drive bay numbers: 
–  Up to eight 2.5-inch SAS/SATA/NVMe drives
Figure 161. 2.5-inch drive bay numbering
–  Up to four 3.5-inch SATA drives
230
ThinkSystem SR670 V2 Maintenance Manual