8.2 Language
Under
code
CO98 you
tan
select the language of the display texts.
The Standard setting is German.
Code
t
Name
Parameter (Factory setting is
printed
in
bofd)
Acceptance
CO98
Language
-O-
German SH + PRG
-l-
English
-2- French
8.3
Display of
actual
valuesAct.
value
Under
Codes
CO50 to CO54 you
tan
read different
atiual
values.
-
Act. value
Output frequency
Act. value of PI controller
Motor voltage
DG
bus voltage
Motor
current
Display
absolute in Hz
with Cl72 =
-O-:
related to
fdmax
with Cl72
=
-1-: absolute in Hz
absolute in
V,H
absolute
in V
absolute in Aeti
8.4 Switch-on display
If
you
connect the controller to the mains, the output frequency is
shown as the first display
(CO50).
If you want to set another
information as switch-on display, enter the corresponding
code
number
under
CO04.
Code
E
Name
CO04 Switch-on
display
Parameter (Factory setting is prlnted in bold)
xxx Code number for display after mains
connection
Acceptance
SH + PRG
8.5
Identification
On the display of the keypad you
tan
see
which
Software
version
is
loaded in the controller. For this, select
code
CO99.
If
you work with LECOM, you
tan
see the controller type
under
co93.
P
0
(d
G
i
-.
3
(d
101