3.5
Features of
setpoint
2
Setpoint
2
tan
only be provided via the differential input
Xl/terminals
1,2,
independently of the selected operating mode
(Cool).
Its value
tan
only be displayed in per
cent
under
code
co49.
Setpoint
2 is processed first by a
special
ramp generator, before it
is added to
setpoint
1
.The ramp times of the ramp generator are
set separately via
C220
and C221.
Code
Name Parameter (Factory setting is printed in bold) Acceptance
C220
Acceleration 5.0
s
0.00 s
{IO
ms}
1
.OO
s ON-LINE
time for
1.0s (100 ms) 10.0s
setpoint
2
10s
11
SI
100s
100s
(101
990
s
c221
Deceleration
5.0 s
0.00 s
(IO
ms)
1.00
s
ON-LINE
time for 1.0
s
{lOO
ms) 10.0s
setpoint
2 10s
(1
SI
100s
100s
(101
990 s
In the factory-set configuration
CO05
= -0-,
setpoint
2 is not active.
If you want to use
setpoint
2, e.g. as additional setpoint, you have
to select another configuration and to set the gain of the
setpoint
channel correspondingly.
Please also note that
setpoint
2 is set to zero as long as a JOG
frequency is active.
In the configurations with dancer-Position
controller
a
diameter
Sensor
is connected to the
differente
input Xi
/
terminals. 1, 2.
3.6
Offset and gain adjustment
Using these
functions
you
tan
eliminate undesired distortions of the
analog input channels and adapt the connected
encoder.
Offset
To compensate offset errors, first apply the
Signal
for the
setpoint
or act. value
=
0. Then select
under
CO25 the corresponding
analog input.
Adjust
the offset correction
under
CO26 such that the
internal display is also set to
Zero.
Internal offset faults are already adjusted before
delivery.
Your
changes
will not be reset when loading the
factory
setting
(CO02 = -o-).
-
-
Input Display
code
Xlherminals
1,2 CO49
Xlherminals
3,4 CO51
Xlherminal
8
CO46
Meaning
Setpoint
2
Actual
value
Setpoint 1
68