9.8.2 Winding or unwinding
Winding from above or from below
The command “unwinding from above” or “unwinding from below”
is given by the
CW/CCW
reversal (reversing command e.g. via
terminals 21 and 22).
Unwinding from above or from below
For unwinding, the sign for the influence of the dancer-Position
Controller must be
inverted.
This achieved by the following:
l Change the polarity of the voltage supply for the dancer
Potentiometer.
l Invert the act. dancer
Signal
at the analog input
l Invert the gain
factor
for the actuat-value
Signal
Invert the dancer-Position
setpoint
at the same time.
The command “unwinding from above” or “unwinding from below”
is given by the
CW/CCW
reversal (reversing command e.g. via
terminals 21 and 22).
9.9
Setting of the PID controller
l The PID controller
tan
only be set
during
Operation (with
material).
Code Name Parameter (Factory setting
is
printed in
hold)
Acceptance
Clfx?.”
Dancer-
1
0.1
111
100 ON-LINE
Position
controller
P-
component Vp
Clfxl’
Dancer-
9999 ms
20 ms (10 ms)
9999
ms ON-LINE
Position
controller
I-
INFO: 9999 ms =
1-component
reset
component Tn
Dancer-
-0.
I-component
active
SH + PRG
Position
-l-
I-component reset
controller reset
I-component
Cl
85*
Dancer-
0.0 0.0
IO.11
5.0 ON-LINE
Position
controller
D-
component kd
Dancer-
-Cl-
D-component actlve SH + PRG
Position
-l-
D-component reset
controller reset
D-component
The 1-component and the D-component
tan
be reset via a freely
assignable terminal, via the keypad or via the serial
interface.