EasyManua.ls Logo

Lenze 8600 series - Adjustment of Analog Inputs

Lenze 8600 series
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.5
Adjustment of analog inputs
l Offset adjustment of the analog input terminals
7/8
(setpoint
input 1) and terminals
1/2
(setpoint input 2):
-
Adjustment only with activated controller inhibit
(e.g.
via low
Signal
at terminal 28).
With the final
configuration
CO05
=
-2Ol-
or
-202-,
an
unwanted Operation of the drive may occur
during
adjustment and activated controller enable. That
means, the drive could accelerate to
fmax
while
adjusting the inputs when the setting controller enable
is activated, although only a very
small
setpoint
was
provided.
For more information
about
the procedure see
chapter
3.6
l Gain adjustment of the analog input, terminals 3, 4
(actual
dancer-Position value):
-
The gain of the input voltage is adapted via a switch
combination of the DIO switch
Sl.
Sl
is located at the left-hand side of the control board
8602MP (board with control terminals). For this, remove the
cover
of the controller.
-
Use
Levellresolution
Remarks
Setpoint 2
-1 ov
to
+l
ov
= diameter
12bit
+ sign
Actual value
-
dancer
-1 OV to
+l
OV
Setting for Standard
1 Pbit + sign
Sensors
Actual value
-
dancer -30V
to
+3OV
12bit
+ sign
Actual value
-
dancer
-60V
to
+6OV
12bit
+ sign
Actual value
-
dancer -90V
to
+9OV
12bit
+ sign
Actual value
-
dancer -120V
to
+12OV
Factory
setting
12bit
+ sign
internal ground (GND)
-
Master voltage or
-lov
to
+lOV
master
current
12bit + sign
(depending on switch
SlI4)
106
-