5
Programming
of
the freely assignable inputs and
Outputs
Most of the inputs and outputs of the frequency controller are
freely assignable via their own
Codes,
i.e. they
tan
be especially
assigned to the required Signals. Furthermore, these
Signals
tan
be adjusted in the best possible way by setting facilities.
In factory setting, these inputs are already assigned to certain
functions.
5.1
Freely assignable digital inputs
Factory setting:
Input
El
r
Function Activation
Set TRIP
HIGH
E2
Reset TRIP HIGH
E3
Activate DC-injection
brake
HIGH
E4, E5, E6
Enable JOG frequencies
HIGH
E7,
E8 Enable additional acceleration and deceleration times
HIGH
-
Changing the functions
If
you
want to assign an input with a function, which has not been
assigned yet, proceed as follows:
l Select the input which you want to assign
under
code
Cl 12.
l
!S.elect
the required function
under
code
Cl 13.
l Determine
under
code
Cl 14 whether the function is to be
activated with a HIGH or with a
LOW
Signal.
l Determine
under
code
Cl 15 whether the function is to be
(activated
always via terminal or, depending on the operating
mode, via the
interface
which has been selected for control
Enable additional acceleration and
deceleration times
Enable JOG frequencies
Activate
DC-injection brake
Integral action component = 0
Ramp generator stop
-10- Ramp-generator input = 0
-2O-
Select Parameter set
-21-
Load Parameter set
-ZOO-
Reset
I-component
dancer-Position controller
-201-
Reset D-component dancer-position controller
-202-
Suppression dancer-Position controller
lenze
81