3.4 Features of setpoint 1
An analog entry of
setpoint
1 is possible via input
Xl/terminal
8,
otherwise it is entered via the keypad or the LECOM
interfaces.
This depends on the selected operating mode
(Cool).
The
configuration
determines whether the input is unipolar, bipolar, or
independently of the operating mode, a digital frequency input.
With terminal control you
tan
read
setpoint
1
under
code
C046.
Under
code
Cl72 you
tan
select whether the
setpoint
is to be
displayed in per
cent
(related to
fdma)
or as absolute value.
With control via keypad or LECOM you
tan
enter
under
Cl
72 how
you Want to enter
setpoint
1, in per
cent
related to
fdmax
or as
absolute value in Hz.
Code (Name Parameter (Factory setting is printed in bold)
IAcceptance
Setpoint
input
Q
Percentage
of
setpoint
1
(COSS)
and
[SH
+
PRG]
actual PI-controller value
(CO51)
-l-
Absolute value of
setpoint
1 (C046) and
actual
PI-controller value (CO51)
Setpoint 1 1
standardized
setpoint
selection: ON-LINE
-100.0 %
[O.l
%)
+lOO.O%
INFO: Refers to maximum field frequency
I
absolute
setpoint
selection:
0.00 Hz (0.01 Hz)
100.00 Hz
100.0 Hz
(0.1 Hz) 480.0 Hz
INFO: adjustable range:
-fdmax
bis
+fdmax
Absolute setpoints
which
are
higher
than the maximum field
frequency, are internally limited to the maximum field frequency
(CO1 1).
3.4.1
Setpoint
input with
master
current
For analog
setpoint
input with
master
current, first
Change
the
switch
setting of
S1/4
on the control board (see page 31). CO34 is used to
determine the setting range.
-
.-
Code Name
Parameter (Factory setting is printed in bold)
CO34
Master current
Q
O...20mA
-l-
4...2OfnA
Acceptance
SH
+
PRG
66