5.2
Functions
of the freely assignable digital inputs
5.2.1 Set TRIP
The
controller
receives a TRIP message via the assigned input.
Using
the
code
Cl 19 and Cl 20, you
tan
program
the monitoring
of the input such that in
case
of fault indications
l these indications are ignored,
l TRIP is activated or
l a warning is activated.
Select the TRIP set input by
entering
Cl 19
=
-0- and
program
the
function via Cl 20 (see page 99).
L
:ode
IName IParameter
(Factory setting is printed in bold)
719
1 Preselection:
I-O-
Dlgltai
Input TRIP-Set
Monitoring
-l-
PTC input
-15
Output power
(1
t monitoring)
320
Function for For Cl19
=
-O-.
-l-
Cl19
-Ck
Monitoring not active
-l-
Monltoring
active,
sets trip
-2-
Monitoring
active,
sets waming
For
Cl19=
-15
Q
Rated power for temperature range up
to 50°C
-1-
Increased power for temperature
range up to 45°C
-2-
Maximum power for temperature
range up to 40°C
Acceptance
SH
+
PRG
t-
SH + PRG
L
5.2.2 Reset TRIP
A fault
which
Causes
a TRIP is automatically displayed
under
CO67
and is indicated e.g. via the relay output. To reset the TRIP
memory, you
tan
use the input
which
is assigned to the TRIP reset
function or press the keys SH + PRG.