Gain
Set the
Signal
gain after the offset adjustment.
First apply
that
Signal
to
which
you want
to
adjust
the internal display
(see offset). Then select
under
CO25 the corresponding analog
input.
Adjust
the
Signal
gain such
that
the desired
setpoint
is
obtained. For the adjustment of the act. value see pages 75 and 77.
:ode
Name
=025
Parameter
Acceptancc
Preselection:
-l-
Analog input Xl/terminals
1/2
SH
+
PRG
Encoder
-2-
Analog input Xl/terminals 3/4
-4
Analog input
Xl/terminal
8
-lO- Digital frequencyfincremental encoder
input X5
-11-
Digital frequency/incremental encoder
input X8
:026 Constant for
CO25
=
-l-,
-2-,
-4-
ON-LINE
CO25
(preselection of the analog inputs):
xxxx mV factory setting
-1000 mV
(1
mvl
+iOOO
mV
CO25
=
-1 o-,
-ll-
ON-LINE
(preselection of the digital-frequency
inputsfincremental encoder inputs):
-l-
512 pulsc/Hz or incrementslrevolution
-2- 1024 pulseklz or incrementslrevolution
-3-
2048 pulse/Hz or incrementslrevolution
-4-
4096 pulse/Hz or increments/revolution
5%
Adjustment for CO25 =
-l-,
-2-, -4- ON-LINE
CO25
(preselection of the analog inputs):
1 .ooo
-2.500 (0.001)
+2
-
CO25
=
-lO-,
-1
l-
(preselection of the digital-frequency
inputs/incremental encoder inputs):
1 .ooo
-5.000 (0.001) +5.000
3.7
Control mode
Under
Code
CO06
you
tan
select V/f-characteristic control or Io
control.
-
Code
E
Name
Parameter
(Factory setting is printed in bold)
Acceptance
CO06
Control mode
-O-
V/f-characteristic control [SH
+
PRG]
-l-
IO
-control
(only for
Single
drives)
-
lmue
69

Table of Contents