3
Basic settings
3.1
Operating mode
The
controllers
of the 8600 series offer different interfaces. From
these you
tan
select
each
one for control and programming.
Controller interfaces for control and programming:
Terminals The terminals are exclusively used to control the
controller.
Keyp’ad
The five keys and the plain text display
tan
be
used mainly for programming. A control via the
keypad is also possible.
LECOM 1
LECOMl
means the connection for
LECOMNB
(connector X6)
which
tan
be used for programming
via a PC or other
master
Systems.
The
Signals
are
processed according to the FIS232 and FIS.485
Standards. You
tan
connect the controller to a
host using the X6 connector.
For
further
information
about
LECOMI
see page 140.
LECOM2 For more sophisticated applications, you
tan
control and
program
the controller via a field bus
connecting module using LECOM2. Here, the field
bus
Systems
InterBus-S
or PROFIBUS with the
DRIVECOM
Profile
are used. For
further
information
about
LECOM2 see page 141.
You
tan
set the desired combination using
code
CO01 “operating
mode”:
--
:0Ck!
--
:001
--
Name
3perating
mode
IParameter (Factory setting is printed in bold)
kceptancr
Control
Parameter setting
-
SH
+
PRG]
-o-
Klemmen Keypad
-l-
Keypad Keypad
.2-
Terminals
LECOM 1 (X6)
.3-
LECOM 1 (X6) LECOM 1 (X6)
-4-
Terminals
LECOM 2
-5-
LECOM 2
LECOM 2
-6-
LECOM 2
Keypad
-7-
LECOM 2
LECOM 1
Please note that the
functions
“controller enable” and “quick stop”
always remain
active
via the assigned terminals, independently of
the selected operating mode.