4.4 Adjustment of the act. value gain
If
you use an incremental encoder for
Speed
control and you have
entered the encoder
constant
as described
under
4.2. (see page
Fehler! Textmarke nicht definiert.)
an adjustment of the act.
value gain is not necessary. For
tacho
act. value, a gain
adjustment is normally required.
4.4.1
Automatic
adjustment
To
adjust
the act. value gain you
tan
activate an automatic
adjustment
under
C029. Proceed as follows:
Activate the closed-loop
Speed
control (COO5) with
Pilot
control
of the output frequency by the controller reference
(C238
=
-l-).
Set the influence of the Pl controller to zero
under
C074.
Idle running. If this should not be possible, please note that the
Slip
of the
machine
is added as gain error
during
the automatic
adjustment. If necessary, set manually.
If
possible, enter 100% setpoint. If the
setpoint
is smaller than
10% an auto-adjustment is not possible.
Enable the controller and wait for the acceleration.
Activate the auto-adjustment via CO29 using SH + PRG.
If the auto-adjustment was successful,
“--ok--”
appears on the
display. If not, please check your settings. With the acceptance
of the auto-adjustment the act. value gain is set
under
C027.
Set
under
CO74 the influence of the PI controller such that the
Slip
occuring
during
Operation
tan
be
controlled.
To set the adjustment time and the gain of the Pl controller see
page
Fehler! Textmarke nicht definiert..
4.4.2 Manual adjustment
If, for technical reasons, the above described automatic
adjustment in idle running is not possible or too inaccurate, you
tan
measure the motor
Speed
by hand and calculate the required
act. value gain. Proceed as follows:
l Activate the closed-loop
Speed
control
(COOS)
with
Pilot
control
of the output frequency by the controller reference
(C238 =
-1-).
l If possible, enter 100% setpoint. If the
setpoint
is smaller, the
obtainable adjustment result is normally less
precise.
l Enable the controller and wait for the acceleration.
Set
under
CO74 the influence of the Pl controller such that the
Slip
occuring
during
Operation
tan
be
controlled.
l Measure the motor
Speed.
-
78