5.2.9
You
tan
store up to four different Parameter
Sets,
for example
when
you want to process different material with one
machine
or if
you want to run different motors with one controller.
Programming of Parameter sets
To
program
several Parameter
Sets,
the following
Steps
are
requ ired:
l Enter all settings for one application.
l Select
code
CO03
and save your Parameter set for example
under
-l-
(Parameter set 1).
l Enter all settings for another application (e.g. different material).
l Select
code
CO03
and save your Parameter set for example
under
-2-
(Parameter set 2) etc.
Code
COO:3
Store
L
Name Parameter (Factory setting is printed in bold)
Parameter set
Z-
Parameter set 1
Parameter set 2
-3-
Parameter set 3
-4-
Parameter set 4
Load Parameter set
Acceptance
SH + PRG
After mains connection, Parameter set 1 is loaded automatically. If
you want to
Change
to other Parametersets using the digital
inputs, every Parameter set must have at least one input with
“Se’lect
Parameter set” and one input with “Load Parameter
Set”.
The number of inputs with the function “Select Parameter
Set”
depends on the number of Parameter sets which you want to use.
Number of additionally required Parameter
Sets
1 Number of required inputs
--
1
I
at least 1
2...3
2
A
maximum
of two inputs
tan
be assigned to this function. For the
assignment
of the inputs see the
notes
on page 81.
A certain Parameter set is loaded when you activate the inputs with
the function “Select Parameter set” according to the table below
and then activate the input “Load Parameter set” with the controller
inhibited.
The input with the smallest number is the first input, the input with
the next highest number is the
second
input, etc. (e.g. El = first
input, E2
=
second
input).
1st input 2nd input
0 0
Parameter set
2
1
0
Parameter
Set 3 0
1
1 1
Please
only activate the input “Load Parameter set” for a short time,
otherwise the selected Parameter is loaded more than once.
The loading of the selected Parameter set will be finished after
max. 0.5 seconds.
If
,all
Parameters are loaded,
under
CO02
it is displayed which Parameter
set was loaded.
-
lenze