9300 Servo PLC
Appendix
4-16
9300ServoPLC EN 1.4
Code LCD
Possible settings
IMPORTANT
Lenze Choice
C0002 Pa r load 0 Load parameter set
0 Load default Load factory setting into RAM
1 Load PS1 Load parameter set 1 into the RAM and
activate
Parameter set1 is loaded
automatically after every mains
connection.
C0003 Pa r sa ve 0 Save parameter set
0 Ready Saving completed
1SavePS1 Non-volatile saving of parameter set 1
11 Save externally Transmit all parameter sets to the
operating unit
C0004 Op-display 56 All available codes Operating display
Operating module shows selected code
in the operating level, if no other status
indications of C0183 are active.
[C0006] Op mode
Å
Operating mode of motor control
Å
depending on C0086
Change of C0086 resets value to the
assigned default setting
Change of C0006 sets C0086 = 0!
^
2-48
2 Servo async Y Servo control asynchronous motors in
star connection
3ServoPM-SMY Servo control synchronous motors in
star connection
22 Servo async Servo control asynchronous motors in
delta connection
C0009 LECOM address 1 1 {1} 99 Controller address
Bus device number when operated via
interface
10, 20, ..., 90 reserved for
broadcast to devicegroups for
RS232,RS485, fibre optics.
C0011 Nmax 3000 500 {1 rpm} 16000 Maximum speed
Reference value for the absolute and
relative setpoint selection for the
acceleration and deceleration times.
Parameter setting via interface:
Large changes in one step should
only be made when the controller is
inhibited.
^
2-48
C0017 FCODE_nC17_a 50 -16000 {1 rpm} 16000 Switching threshold n
act.
<n
x
r
act.
< C0017 activates the
comparator output CMP1-OUT
^
2-45
C0018 fchop 1 Chopping frequency
^
2-48
0 16/8 kHz sin Optimum noise reduction with
automatic change-over to 8 kHz
18kHzsin Operation with optimum power
216kHzsin Noise optimised operation
C0019 Thresh nact=0 0 0 {1 rpm} 16000 Threshold when n
act.
= 0 is recognized.
C0022 Imax current
Å
0 {0.01 A} 1.50 I
N
I
max
limit
Å
depending on C0086
Change of C0086 resets value to the
assigned factory setting (1.5*Imotor)
^
2-48