6. Programmer's Reference VINX-1x0-HDMI Extenders – User's Manual 60
6.5.10. Setting a Static Gateway Address
DIFFERENCE: Make sure the IP address setting is static:
In case of FW 1.x.x: when the DhcpEnabled property is false you can set a static IP address.
In case of FW 2.x.x: when the IpSetupMode property is static you can set a static IP address.
Command and Response
ç
æ
Example
ç
æ
ç
æ
INFO: The applySettings method will save and apply the new value and results the extender to reboot.
6.6. Encoder-related Commands
6.6.1.
The input port can be queried if video signal is present.
Command and Response #status
ç <in>.SignalPresent
æ <in>
Parameters
If the parameter is 0, then signal is not present at the port. If the value is 1, then signal is
present at the input.
Example
ç
æ
6.6.2.
The resolution and the refresh rate of the incoming video signal can be queried.
Command and Response #resolution
ç <in>.Resolution
æ <in>
Example
ç
æ
6.6.3.
DIFFERENCE: Below command is valid for VINX-210AP-HDMI-ENC device only.
Command and Response
ç
æ
Parameters
Parameter description Parameter values
0: unknown
1: HDMI
2: VGA
Example
ç
æ
6.6.4.
DIFFERENCE: Below command is valid for VINX-210AP-HDMI-ENC device only.
Command and Response #inputselection
ç
æ
Parameters
Parameter description Parameter values
The currently applied input
selection method.
0: Auto
1: HDMI
2: VGA
Auto mode:
If sync is lost for at least 3 seconds, a switch over to the other source shall occur. No automatic switch back
to the original input shall occur when the signal is restored.
Example
ç
æ