Installation...Water connections
1-13
LTO
1.4.2.2 PROCEDURE
 Flow chart
To connect the water supply to the edger and fit the pipes, follow the procedure below:
Flow chart 1-3: Pipe connections
#1 Check that the machine is switched off: On/Off switch OFF and mains plug
disconnected.
#2 Check that the water supply is closed.
#3 Ensure that the machine is level => screw or unscrew the four feet.
#4 Connect the water drain pipe to the chassis.
#5 Fit the filter seal between the water supply connection and the valve if you
operate in direct water supply.
#6 Connect the water supply pipe to the valve (if direct water) or to the pump
(in closed circuit).
#7 Connect the used water discharge pipe if you operate in direct water supply.
#8 When the water circuit is being filled, check the watertightness of the unit,
especially around the solenoid valves.
#9 If operating in closed circuit, connect the pump supply to the pump power
connector.