Application Manual CDA3000
5-11
5 Software functions
1
2
3
4
5
6
A
DE
EN
FR
Parameters written to during auto-tuning of the device are retained when
a new application data set is selected. Switching user data set does over-
write the auto-tuning parameters, however. The auto-tuning should there-
fore be performed before parameter setting of the user data sets (UDS).
Auto-tuning parameters
Used in control
mode
VFC SFC FOR
_15FC Initial commissioning, section 5.1
160-MOJNM Mass moment of inertia of motor
161-SCJ1 CDS1: Mass moment of inertia of system
162-SCJ2 CDS2: Mass moment of inertia of system
_64 CA Current-controlled startup
641-CLCL1 CDS1: Current limit, current-controlled startup
642-CLFL2 CDS1: Lowering frequency, current-controlled startup
643-CLFR1 CDS1: Initial frequency, current-controlled startup
646-CLCL2 CDS2: Current limit, current-controlled startup
647-CLFL2 CDS2: Lowering frequency, current-controlled startup
648-CLFR2 CDS2: Initial frequency, current-controlled startup
_70VF Voltage frequency control, section 6.1.1
700-VB1 CDS1: Boost voltage
701-VN1 CDS1: Motor rated voltage
702-FN1 CDS1: Motor rated frequency
715-VB2 CDS2: Boost voltage
716-VN2 CDS2: Motor rated voltage
717-FN2 CDS2: Motor rated frequency
_74IR IxR load compensation, section 6.1.2
741-KIXR1 CDS1: IxR compensation factor
743-KIXR2 CDS2: IxR compensation factor
_75SL Slip compensation, section 6.1.3
751-KSC1 CDS1: Slip compensation factor
753-KSC2 CDS2: Slip compensation factor
Table 5.6 Parameters changed during auto-tuning