5  Software functions
Parameters of the reference structure
Parameter Function Value range FS Unit Online
280-RSSL1 Reference selector 1 see Table 5.25 FMAX
281-RSSL2 Reference selector 2 see Table 5.25 FCON
282-FA0 Analog reference input ISA00 * 0 Hz
283-FA1 Analog reference input ISA01 * 0 Hz
284-FSIO Reference serial interface * 0 Hz
285-FPOT Reference of MOP * 0 Hz
286-FDIG
Digital reference input (reference cou-
pling)
* 0 Hz
287-FOPT1 Reference value of option slot 1 * 0 Hz
288-FOPT2 Reference value of option slot 2 * 0 Hz
289-SADD1 Offset value for reference selector 1 0 ... 11 10
290-SADD2 Offset value for reference selector 2 0 ... 11 0
291-REF1 Reference value of reference channel 1 * Hz
292-REF2 Reference value of reference channel 2 * Hz
293-REF3 Reference before reference limitation * Hz
294-REF4 Reference before ramp generator * Hz
295-REF5 Reference before ramp smoothing * Hz
296-REF6 Reference for transfer to control * Hz
297-RF1FA Factor for reference channel 1 0 ... 100 100 %
Table 5.24 Parameters from subject area _28RS Reference structure
Explanatory notes
• Parameter values which are produced from calculations and so are
not editable have an asterisk (*) in the “Value range” column.
• The offset value for the reference selector is entered as a purely
decimal number.