Application Manual CDA3000
5-43
5  Software functions
1
2
3
4
5
6
A
DE
EN
FR
A Reference sources
B Reference selectors (RSSLx) with offset function (SADDx)
C Reference adjustment, percentage
D Possibility of inversion
E Reference limitation (amount only)
F Ramp generator
G Activate/deactivate smoothing (inactive in table FFTB)
H Driving profile generator
J MOP function
(1) Table with 8 driving sets, incl. acceleration and braking ramps
Figure 5.14 Parameters from subject area _28RS Reference structure
Explanatory notes to Figure 5.14
4. Smoothing time: The filter smoothes the beginning
and end of the ramp to limit bucking. The acceleration
and braking times are extended by the smoothing time
(0 to 2000 ms).
When the driving sets are used the smoothing time is
deactivated.
 Symbol Meaning
Reference source (input), e.g. with second characteristic data set
Reference selector (switch)
Mathematical influence
Interim reference values (for display only)
Limitation of reference value (upper limit)
Table 5.23 Symbols used in Figure 5.14