Application Manual CDA3000
5-97
5 Software functions
1
2
3
4
5
6
A
DE
EN
FR
Parameters for motor holding brake
Settings of digital outputs for motor holding brake
Parameter Function Value range FS Unit Online
310-FBCW Frequency limit for motor
brake in clockwise running
0 ... 1600 3 Hz
311-FBCCW Frequency limit for motor
brake in anti-clockwise
running
-1600 ... 0 -3 Hz
312-FBHYS Hysteresis for operation point
of motor holding brake
0 ... 1600 1 Hz
Table 5.57 Parameters from subject area _31MB Motor holding brake
Setting Function
F
O
S
D
0
F
O
S
D
1
F
O
S
D
2
F
O
S
E
x
BRK1 Output is set when the actual speed has
exceeded the value in parameter FBCxx
(clockwise: FBCW, anti-clockwise: FBCCW).
BRK2 Output is set if the actual speed has
exceeded the value in parameter FBCxx and
current is flowing in all motor phases
(clockwise: FBCW, anti-clockwise: FBCCW).
Table 5.58 Settings for FOxxx of digital outputs for motor holding brake
Explanatory notes
The frequency limit for engagement of the holding brake can be set
independently for clockwise and anti-clockwise running.
The optional monitoring of the motor current (BRK2) provides the
security when the holding brake is opened that the motor is correctly
connected and has already developed torque.