Application Manual CDA3000
5-97
5  Software functions
1
2
3
4
5
6
A
DE
EN
FR
Parameters for motor holding brake
Settings of digital outputs for motor holding brake
Parameter Function Value range FS Unit Online
310-FBCW Frequency limit for motor 
brake in clockwise running
0 ... 1600 3 Hz
311-FBCCW Frequency limit for motor 
brake in anti-clockwise 
running
-1600 ... 0 -3 Hz
312-FBHYS Hysteresis for operation point 
of motor holding brake
0 ... 1600 1 Hz
Table 5.57 Parameters from subject area _31MB Motor holding brake
Setting Function
F
O
S
D
0
F
O
S
D
1
F
O
S
D
2
F
O
S
E
x
BRK1 Output is set when the actual speed has 
exceeded the value in parameter FBCxx 
(clockwise: FBCW, anti-clockwise: FBCCW).
   
BRK2 Output is set if the actual speed has 
exceeded the value in parameter FBCxx and 
current is flowing in all motor phases 
(clockwise: FBCW, anti-clockwise: FBCCW).
   
Table 5.58 Settings for FOxxx of digital outputs for motor holding brake
Explanatory notes
• The frequency limit for engagement of the holding brake can be set
independently for clockwise and anti-clockwise running.
• The optional monitoring of the motor current (BRK2) provides the
security when the holding brake is opened that the motor is correctly
connected and has already developed torque.