Application Manual CDA3000
5-101
5  Software functions
1
2
3
4
5
6
A
DE
EN
FR
Example: Setting F1 of MOP function
A digital potentiometer is operated by way of two digital inputs. One input
reduces the reference value, the other increases it. At the analog input
ISA0x a base value can be set as the analog speed reference FSIN, so
the digital inputs act as an offset. The MOP function assigns the refe-
rence source FPOT a reference value.
(1) Reset reference to base value
Figure 5.35 Basic function with reset to base value (corresponds to
settingF1inTable5.61)
0
Offset
Offset
Basis
ACCRx
DECRx
FMAX
FSIN
(1)
0
1
0
1
0
1
Start
t [ms]
f [Hz]
MP_UP
MP_DN