Parameters for the ramp generator
Note: Dynamic acceleration and deceleration results in high startup
and braking currents. This also applies to the emergency stop
by way of the stop ramp. In deceleration the motor drops into
regenerative operation and increases the DC-link voltage
(DCV).
Parameter Function Value range FS Unit Online
590-ACCR1 CDS1: Acceleration ramp 0 ... 999 20 Hz/s
*
591-ACCR2 CDS2: Acceleration ramp 0 ... 999 20 Hz/s
*
592-DECR1 CDS1: Deceleration ramp 0 ... 999 20 Hz/s
*
593-DECR2 CDS2: Deceleration ramp 0 ... 999 20 Hz/s
*
594-STPR1 CDS1: Stop ramp 0 ... 999 20 Hz/s
*
595-STPR2 CDS2: Stop ramp 0 ... 999 20 Hz/s
*
596-JTIME Smoothing time of sinusoidal ramp 0 ... 10000 0 ms
597-RF0 Response at reference value 0 Hz OFF / 0 Hz OFF -
* from firmware V. 2.10
Table 5.63 Parameters from subject area _59DP Driving profile generator
Explanatory notes
• If one of the two ramps (acceleration ramp ACCRx, deceleration
ramp DECRx) of a characteristic data set is set to 0 (zero), both
ramps are inactive.
• The DC braking function has priority over the stop ramp STPRx.
• Standard control signals with the assignment of the ramps are set
out in Table 5.29 (section 5.2.7).
• The ramp values can only be changed online as from firmware V.
2.10.