Parameters of voltage frequency control
Parameter Function Value range FS Unit Online
700-VB1 CDS1: Boost voltage 0 ... 100 0 V
701-VN1 CDS1: Motor rated voltage 0 ... * * V
702-FN1 CDS1: Motor rated frequency 0 ... 1600 50 Hz
703-V1-1 CDS1: Voltage buffer value 1 0 ... * 0 V
704-V2-1 CDS1: Voltage buffer value 2 0 ... * 0 V
705-V3-1 CDS1: Voltage buffer value 3 0 ... * 0 V
706-V4-1 CDS1: Voltage buffer value 4 0 ... * 0 V
707-V5-1 CDS1: Voltage buffer value 5 0 ... * 0 V
708-V6-1 CDS1: Voltage buffer value 6 0 ... * 0 V
709-F1-1 CDS1: Frequency buffer value 1 0 ... 1600 0 Hz
710-F2-1 CDS1: Frequency buffer value 2 0 ... 1600 0 Hz
711-F3-1 CDS1: Frequency buffer value 3 0 ... 1600 0 Hz
712-F4-1 CDS1: Frequency buffer value 4 0 ... 1600 0 Hz
713-F5-1 CDS1: Frequency buffer value 5 0 ... 1600 0 Hz
714-F6-1 CDS1: Frequency buffer value 6 0 ... 1600 0 Hz
715-VB2 CDS2: Boost voltage 0 ... 100 0 V
716-VN2 CDS2: Motor rated voltage 0 ... * * V
717-FN2 CDS2: Motor rated frequency 0 ... 1600 50 Hz
718-V1-2 CDS2: Voltage buffer value 1 0 ... * 0 V
719-V2-2 CDS2: Voltage buffer value 2 0 ... * 0 V
720-V3-2 CDS2: Voltage buffer value 3 0 ... * 0 V
721-V4-2 CDS2: Voltage buffer value 4 0 ... * 0 V
722-V5-2 CDS2: Voltage buffer value 5 0 ... * 0 V
723-V6-2 CDS2: Voltage buffer value 6 0 ... * 0 V
724-F1-2 CDS2: Frequency buffer value 1 0 ... 1600 0 Hz
725-F2-2 CDS2: Frequency buffer value 2 0 ... 1600 0 Hz
726-F3-2 CDS2: Frequency buffer value 3 0 ... 1600 0 Hz
727-F4-2 CDS2: Frequency buffer value 4 0 ... 1600 0 Hz
728-F5-2 CDS2: Frequency buffer value 5 0 ... 1600 0 Hz
729-F6-2 CDS2: Frequency buffer value 6 0 ... 1600 0 Hz
730-ASCA1
CDS1: Assistance parameter for Voltage 
Frequency Control
see Table 6.4 OFF
731-ASCA2
CDS2: Assistance parameter for Voltage 
Frequency Control
see Table 6.4 OFF
Table 6.3 Parameters from subject area _70VF Voltage frequency con-