_65 CS-Characteristic data switchover (CDS), from page 5-112
650 CDSAC Activate characteristic data set (CDS) 0 2 15 USIGN8 RAM C V
651 CDSSL Control location for switchover of character-
istic data set (CDS)
OFF 2 3 USIGN8 FLASH
652 FLIM Hz Limit frequency for switchover CDS 2 20 2 3 INT32Q16 FLASH
_66 MS-Master/-Slave operation, from page 5-114
837 MSFCT Master/-Slave coupling factor (FDIG) 1 4 4 INT32Q16 FLASH
838 MSECT ms Error trigger time in case of failure of refer-
ence master
0 4 4 USIGN16 FLASH
_67 BR-DC braking, from page 5-117
670 BRDC Mode of actuation of DC braking OFF 3 3 USIGN8 FLASH
671 BRDCC Braking current for DC braking 80 3 3 USIGN16 FLASH
672 BRTMX s Maximum DC braking time 15 3 3 USIGN16 FLASH
673 BRTOF s Demagnetization time before DC braking 2.00 4 4 FIXPT16 FLASH
674 BRTMN ms Minimum DC braking time 0 3 3 USIGN16 FLASH
_68 HO-DC holding, from page 5-120
680 HODCC DC holding current 60 3 3 USIGN16 FLASH
681 HODCT s DC holding time 3.00 3 3 FIXPT16 FLASH
_69 PM-Modulation, from page 5-129
690 PMFS Switching frequency of power stage G 4 4 USIGN8 FLASH
_70VF-Voltage Frequency Control, from page 6-8
700 VB1 V CDS 1: Boost voltage G 3 3 FLOAT32 FLASH
701 VN1 V CDS 1: Motor rated voltage G 3 3 FLOAT32 FLASH
702 FN1 Hz CDS 1: Motor rated frequency 50 3 3 FLOAT32 FLASH
703 V1-1 V CDS 1: Voltage buffer value 1 0 4 4 FLOAT32 FLASH
704 V2-1 V CDS 1: Voltage buffer value 2 0 4 4 FLOAT32 FLASH
705 V3-1 V CDS 1: Voltage buffer value 3 0 4 4 FLOAT32 FLASH
706 V4-1 V CDS 1: Voltage buffer value 4 0 4 4 FLOAT32 FLASH
707 V5-1 V CDS 1: Voltage buffer value 5 0 4 4 FLOAT32 FLASH
708 V6-1 V CDS 1: Voltage buffer value 6 0 4 4 FLOAT32 FLASH
709 F1-1 Hz CDS 1: Frequency buffer value 1 0 4 4 FLOAT32 FLASH
710 F2-1 Hz CDS 1: Frequency buffer value 2 0 4 4 FLOAT32 FLASH
711 F3-1 Hz CDS 1: Frequency buffer value 3 0 4 4 FLOAT32 FLASH
712 F4-1 Hz CDS 1: Frequency buffer value 4 0 4 4 FLOAT32 FLASH
713 F5-1 Hz CDS 1: Frequency buffer value 5 0 4 4 FLOAT32 FLASH
714 F6-1 Hz CDS 1: Frequency buffer value 6 0 4 4 FLOAT32 FLASH
715 VB2 V CDS 2: Boost voltage G 3 3 FLOAT32 FLASH
716 VN2 V CDS 2: Motor rated voltage G 3 3 FLOAT32 FLASH
717 FN2 Hz CDS 2: Motor rated frequency 50 3 3 FLOAT32 FLASH
718 V1-2 V CDS 2: Voltage buffer value 1 0 4 4 FLOAT32 FLASH
719 V2-2 V CDS 2: Voltage buffer value 2 0 4 4 FLOAT32 FLASH
720 V3-2 V CDS 2: Voltage buffer value 3 0 4 4 FLOAT32 FLASH
721 V4-2 V CDS 2: Voltage buffer value 4 0 4 4 FLOAT32 FLASH
722 V5-2 V CDS 2: Voltage buffer value 5 0 4 4 FLOAT32 FLASH
723 V6-2 V CDS 2: Voltage buffer value 6 0 4 4 FLOAT32 FLASH
No. Name Unit Function
Factory
set.
Your set. R W
Data
type
Memory