Appendix A Overview of parameters
724 F1-2 Hz CDS 2: Frequency buffer value 1 0 4 4 FLOAT32 FLASH
725 F2-2 Hz CDS 2: Frequency buffer value 2 0 4 4 FLOAT32 FLASH
726 F3-2 Hz CDS 2: Frequency buffer value 3 0 4 4 FLOAT32 FLASH
727 F4-2 Hz CDS 2: Frequency buffer value 4 0 4 4 FLOAT32 FLASH
728 F5-2 Hz CDS 2: Frequency buffer value 5 0 4 4 FLOAT32 FLASH
729 F6-2 Hz CDS 2: Frequency buffer value 6 0 4 4 FLOAT32 FLASH
730 ASCA1 Assistance parameter for Voltage Frequency
Control in CDS 1
OFF 1 2 USIGN8 FLASH
731 ASCA2 Assistance parameter for Voltage Frequency
Control in CDS 2
OFF 1 2 USIGN8 FLASH
_74 IR-IxR load compensation, from page 6-13
740 IXR1 CDS 1: I*R load compensation on/off ON 3 3 USIGN8 FLASH
741 KIXR1 Ohm CDS 1: I*R compensation factor G 3 3 FLOAT32 FLASH
742 IXR2 CDS 2: I*R load compensation on/off ON 3 3 USIGN8 FLASH
743 KIXR2 Ohm CDS 2: I*R compensation factor G 3 3 FLOAT32 FLASH
744 IXRTF s Filter time constant for IxR compensation 0.01 3 3 FLOAT32 FLASH
_75 SL-Slip compensation, from page 6-16
750 SC1 CDS 1: Slip compensation on/off OFF 3 3 USIGN8 FLASH
751 KSC1 CDS 1: Slip compensation factor G 3 3 FLOAT32 FLASH
752 SC2 CDS 2: Slip compensation on/off OFF 3 3 USIGN8 FLASH
753 KSC2 CDS 2: Slip compensation factor G 3 3 FLOAT32 FLASH
754 KSCTF s Filter time constant for slip compensation 0.01 3 3 FLOAT32 FLASH
_76 CI-Current injection, from page 6-18
760 CICN1 CDS 1: Current injection reference G 3 3 USIGN16 FLASH
761 CIFM1 Hz CDS 1: Current injection limit frequency G 3 3 FLOAT32 FLASH
762 CIFR1 Hz CDS 1: Current injection transition range 2 4 4 FLOAT32 FLASH
763 CICN2 CDS 2: Current injection reference G 3 3 USIGN16 FLASH
764 CIFM2 Hz CDS 2: Current injection limit frequency G 3 3 FLOAT32 FLASH
765 CIFR2 Hz CDS 2: Current injection transition range 2 4 4 FLOAT32 FLASH
_77 MP-Remagnetization, from page 5-134
770 MPCN1 CDS 1: Magnetizing current 33 3 3 USIGN16 FLASH
771 MPT1 s CDS 1: Magnetization time 0.00 3 3 FIXPT16 FLASH
772 MPCN2 CDS 2: Magnetizing current 33 3 3 USIGN16 FLASH
773 MPT2 s CDS 2: Magnetization time 0.00 3 3 FIXPT16 FLASH
774 MPT s Magnetization time for SFC and FOR 0.50 3 3 FIXPT16 FLASH
_78SS Speed controller SFC, from page 6-33
780 SSGF1 CDS 1: Scaling of speed controller gain 100.00 3 3 FIXPT16 FLASH
781 SSG1 CDS 1: Speed controller gain 1 3 4 FLOAT32 FLASH
782 SSTL1 s CDS 1: Speed controller lag time G 4 4 FLOAT32 FLASH
783 SSTF1 s CDS 1: Filter time constant of speed estimate G 4 4 FLOAT32 FLASH
784 SSGF2 CDS 2: Scaling of speed controller gain 100.00 3 3 FIXPT16 FLASH
785 SSG2 CDS 2: Speed controller gain 1 3 4 FLOAT32 FLASH
786 SSTL2 s CDS 2: Speed controller lag time G 4 4 FLOAT32 FLASH
787 SSTF2 s CDS 2: Filter time constant of speed estimate 0.02 4 4 FLOAT32 FLASH