Application Manual CDA3000
A-11
Appendix A Overview of parameters
1
2
3
4
5
6
A
DE
EN
FR
_79 EN-Encoder evaluation, from page 6-50
790 ECLNC Lines per revolution of encoder 1024 2 3 USIGN16 FLASH
_80 CC-Current control, from page 6-56
800 CCG Current controller gain G 4 4 FLOAT32 FLASH
801 CCTLG s Current controller lag time G 4 4 FLOAT32 FLASH
802 CCTF s Filter time constant for current measurement 0.01 4 4 FLOAT32 FLASH
803 VCSFC Correction factor of fault voltage
characteristic
70 4 4 USIGN8 FLASH
804 CLIM1 CDS 1: Maximum reference current for
current control
100 3 3 USIGN16 FLASH
805 CLIM2 CDS 2: Maximum reference current for
current control
100 3 3 USIGN16 FLASH
_81SC-Speed controller FOR, from page 6-54
810 SCGF1 CDS 1: Scaling of speed controller gain 100.00 3 3 FIXPT16 FLASH
811 SCG1 CDS 1: Speed controller gain 1 3 4 FLOAT32 FLASH
812 SCTL1 s CDS 1: Speed controller lag time 0.02 4 4 FLOAT32 FLASH
813 SCTF1 s CDS 1: Jitter filter time constant 0.001 4 4 FLOAT32 FLASH
814 SCGF2 CDS 2: Scaling of speed controller gain 100.00 3 3 FIXPT16 FLASH
815 SCG2 CDS 2: Speed controller gain 1 3 4 FLOAT32 FLASH
816 SCTL2 s CDS 2: Speed controller lag time 0.02 4 4 FLOAT32 FLASH
817 SCTF2 s CDS 2: Jitter filter time constant 0.001 4 4 FLOAT32 FLASH
818 SCGF0 Speed controller gain at frequency zero 10.00 3 3 FIXPT16 FLASH
_84 MD-Motor data, from page 5-132
839 MONAM Symbolic motor name (max. 64 characters) 3 3 STRING FLASH
840 MOFNM Vs Nominal pole flux G 4 5 FLOAT32 FLASH
841 MOL_S H Leakage inductance G 4 5 FLOAT32 FLASH
842 MOR_S Ohm Stator resistance G 4 5 FLOAT32 FLASH
843 MOR_R Ohm Rotor resistance G 4 5 FLOAT32 FLASH
844 MONPP Number of pole pairs of motor 2 4 5 USIGN8 FLASH
850 MOL_M H Magnetizing inductance from mag.
characteristic
G 4 15 FLOAT32 RAM A C
_86SY System
4 PROG Reset device to factory setting 2 4 4 USIGN16 FLASH
15 PLRDY Activate control initialization OFF 4 4 USIGN8 RAM C V
Menu control KP200
8 GROUP Subject area of KP200 _15FC 1 1 USIGN8 RAM C V
VAL menu actual value parameter
14 ACTT Nm Actual torque 0 1 7 INT32Q16 RAM A C
86 TSYS min System time after power-up in [min]. 0 3 15 USIGN16 RAM A C
87 TOP h Operating hours meter 0 3 7 USIGN16 FLASH
400 ACTF Hz Current actual frequency 0 1 15 INT32Q16 RAM A C
401 ACTN rpm Actual speed 0 1 15 INT32Q16 RAM A C
404 VMOT V Output voltage of inverter 0.00 1 15 FIXPT16 RAM A C
405 DCV V DC-link voltage 0.00 1 15 FIXPT16 RAM A C
406 REFF Hz Current reference frequency 0 1 15 INT32Q16 RAM A C
No. Name Unit Function
Factory
set.
Your set. R W
Data
type
Memory
type