4-24
Application Manual CDA3000
4  Application data sets
User module UM-8I4O inputs and outputs
IED00 214-FIE00 Function selector digital input IED00 OFF SADD1
IED01 215-FIE01 Function selector digital input IED01 OFF FFTB0
IED02 216-FIE02 Function selector digital input IED02 OFF FFTB1
IED03 217-FIE03 Function selector digital input IED03 OFF FFTB2
IED04 218-FIE04 Function selector digital input IED04 OFF /LCW
IED05 219-FIE05 Function selector digital input IED05 OFF /LCCW
IED06 220-FIE06 Function selector digital input IED06 OFF UM0
IED07 221-FIE07 Function selector digital input IED07 OFF UM1
OED00 243-FOE00 Function selector digital output OED01 OFF WIIT
OED01 244-FOE01 Function selector digital output OED01 OFF WIT
OED02 245-FOE02 Function selector digital output OED02 OFF WIS
OED03 246-FOE03 Function selector digital output OED03 OFF WOTD
Reference structure
280-RSSL1 Reference selector 1 FMAX
289-SADD1 Offset for reference selector 1 10 0 9
Current-controlled acceleration
640-CLSL1
CDS1: Current-controlled startup function 
selector
CCNFS OFF OFF
645-CLSL2
CDS2: Current-controlled startup function 
selector
CWFS OFF OFF
Characteristic switchover
651-CDSSL Characteristic data set switchover OFF TERM
I/O Parameter Function
152-ASTER =
DRV_1 
(FS)
DRV_2 DRV_3 DRV_4 DRV_5
1) After setting the parameters of the user data sets, change parameter value 166-UDSSL from PARAM (KEYPAD KP200,
D
RIVEMANAGER) to TERM (terminal operation).
Table 4.12 Automatic changes by means of the assistance parameter
An empty line means that the setting is the same as for DRV_1 (factory set-
ting).