EasyManua.ls Logo

Lust CDA3000 - Page 77

Lust CDA3000
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Manual CDA3000
4-25
4 Application data sets
1
2
3
4
5
6
A
DE
EN
FR
Active functions with traction and lifting drive
More details of the software functions and setting options are presented
in section 5 Software functions and section 6 Control modes.
Function Effect VFC SFC FOR
IxR load compensation
In case of load surges a higher torque
is available, and the motor heats up
less.
Current injection Increase in starting torque
Current-controlled start-
up with ramp stop
Protection against current overload
shut-off in acceleration of large
moments of inertia

to
V. 1 .40
DC holding
Rotation of the motor shaft without
load is counteracted.
Magnetizing
Increase in startup and standstill tor-
que

Table4.13 Activefunctions

Table of Contents